Flow Cytometry -- Abdominal Pain


FLOW CYTOMETRY:

INTERPRETATION:

The flow cytometric immunophenotypic studies was not entirely conclusive due to the relatively low viability. The results demonstrate a CD5 negative, CD10 positive monoclonal kappa positive B-cell population. There are also admixed heterogeneous T-cells.

RESULTS:

Cell suspension immunophenotypic studies were performed on liver and two regions were analyzed.

Region 1 represents the small, non-complex cells (16% of the events).
Region 2 represents the large, non-complex cells (2% of the events).

VIABILITY: 60%

B Cells R1 R2
Antigen Usual Specificity % Positive
Kappa+ B Cell Subset 14 73
Lambda+ B Cell Subset 1 0
Kappa:Lambda 14.0 > 73.0
CD19+ B Cell 19 81
CD19+/CD5+ B Cell Subset 2 3
CD20+ B Cell 13 68
CD10 (Calla) B Cell Subset 15 80

T Cells R1 R2
Antigen Usual Specificity % Positive
CD2+ T Cell 82 17
CD3+ Total T Cell 79 13
CD5+/CD19- T Cell 78 12
CD7+ T Cell 70 15
CD4+/CD8- T Helper 49 11
CD8+/CD4- T cytotoxic/suppressor 26 2
CD4+/CD8+ T Cell Subset 4 2
CD4:CD8 T Helper:Suppressor ratio 1.9 5.5
CD16, CD56+/CD3+ T Cell Subset 3 2
CD16, CD56+/CD3- NK Cell 2 4

Additional Antibodies R1 R2
Antigen Usual Specificity % Positive
CD45+ Leukocytes 99 96


MOLECULAR DIAGNOSTICS

FINAL DIAGNOSIS


Case 